WHAT SMOKE ALARM DETECTS BEST?

Air-sampling Smoke Detectors work by:
  1. Continually drawing air into a pipe network attached to a detector unit.
  2. Passing the air through a dual stage filter to remove dirt 
  3. Sending the clean air to a laser detection chamber for smoke detection.
  4. Measuring the light scatter caused by any smoke
  5. Processing the detector signal and presenting the smoke level graphically
  6. Communicating the information to a fire alarm control panel, a software management system or a building management system.

View a  larger version of the image.


How VESDA detectors work - small

What's so great about smoke detection systems? Why are they the smoke alarm that detects best? What makes them so different from other detection systems?

Here are some of the key benefits of a system.

Detectors provide the earliest possible warning of a fire event
Aspirating smoke detectors provide the earliest possible warning of an imminent fire hazard. Why is this important? It buys time. Time to investigate a smoke alarm. Time to take action. Time to avoid the danger, damage and distruption caused by fire.

To illustrate the advantage that a system provides, let's look at how a fire progresses: Fire

All fires (both smoldering and fast flaming types) are comprised of four stages: Incipient (Pre-Combustion), Visible Smoke, Fast Flaming and Intense Heat.

Notice how smoke levels are extremely low in the first stage (Incipient Stage) of a fire and rise dramatically as the fire ignites and begins to burn, sometimes uncontrollably.

This Incipient Stage and it is by far the most docile stage of the fire. During this stage, the density of the smoke is so low that it is virtually invisible to the human eye and below the detectable range of conventional devices.

During the second stage, (Visible Smoke), smoke becomes more visible and reaches a critical density. It is only at this late point in the progression of the fire that conventional-type smoke detection systems alarm to the presence of smoke.

Smoke becomes more visable when it transitions into the third stage (Flaming Fire). This is where smoke density increases, and flaming fire erupts, narrowing response options, increasing danger and damage, which results in business disruption.

During stage four, (Intense Heat), both smoke density and flaming fire increase exponentially, causing devastating damage and triggering fire suppression systems.

Clearly the BEST time for detection is the incipient stage, the point where damage is minimized and response options maximized, and it is here where affords you a critical advantage: ... time

Fire
monitors the entire progression of a fire - easily detecting fire long before smoke is visible and long before any other forms of detection.

With the world's widest sensitivity range, produces multi-level warnings at the very early stage of an impending fire. This provides the valuable time necessary to initiate a flexible, appropriate response. Within the Incipient Stage of the fire, easily detects minute levels of smoke present in the air and offers up to three levels of alarm, all with adjustable thresholds, before there is visible smoke, flaming fire, or intense heat, and often long before disruption, damage, or injury can take place.

To provide complete protection, offers a fourth alarm, Fire 2, operating throughout the later stages of a fire. Fire 2 is typically programmed to release suppression.

This enormously wide range allows a single detector to uniquely monitor the entire progression of a fire.

Back to Top



Detectors are suitable to a wide range of applications
detectors provide solutions for a diverse group of applications ranging from small areas, or cabinets to large open spaces. Below is a partial list of areas where systems can be used.

Telecommunications: systems are installed worldwide in these mission critical facilities, and maintain national supply agreements with the world’s leading telecommunication organizations.

Cultural Facilities: Concealed sampling techniques possible with a system make it virtually undetectable, while very early detection helps to avoid suppression release.

Correctional Facilities: In areas where maintenance access is difficult, or vandalism is an issue, detectors can be mounted in one central area outside of the protected location. All maintenance and testing can be performed at the detector.

Data Centers: detectors provide "Peace of Mind" while protecting valuable data in financial data centers, stock exchanges, and other areas where electronics drive today’s modern businesses.

Manufacturing: products help to avoid costly production stops in semi-conductor manufacturing plants, as well as other controlled facilities.

Warehousing: products provide solutions for high value warehousing including archive storage, high-rack, and difficult environments such as refrigerated stores and hazardous good storage.

Back to Top



Very early detection without false alarms
When installed properly, Air Sampling Smoke Detectors are virtually free from nuisance or false alarms. The ability to set time delays, and unique advanced features such as AutoLearn and Referencing, all work to ensure nuisance alarms are not the source of business disruption. These features allow a detector to automatically adjust itself to the ambient environment being monitored. This ensures the systems will maintain their sensitivity and reliability, and freedom from nuisance alarms, in virtually any environment.

Back to Top



Xtralis provides solutions to your unique applications by applying the latest in fire science
Xtralis Pty Ltd is the world leader in providing Air Sampling Smoke Detection solutions, and has manufactured more air sampling detectors than any other company in the world. The company develops, creates and delivers high value technology-rich products and services to large and growing international markets.

Xtralis Pty Ltd operates a global network of companies in the Americas, as well as Australia, Asia, the United Kingdom and throughout other areas of Europe.

For more than two decades we have gained extensive application knowledge. Knowledge that you can tap into to solve the most difficult fire protection problems.

Beyond our state of the art smoke detection system, Xtralis provides application solutions utilizing:
  • FDS - Fire Modeling
  • Performance Based Designs
  • Non invasive, in situ testing and design validation.
With its advanced integration capabilities and an acute understanding of operational efficiencies, Xtralis continues to offer seamless fire solutions to suit the demands of today’s business. Xtralis is committed to providing a continuous flow of intelligent, sophisticated products that significantly improve the safety and security of its customers.

Back to Top



Xtralis offers excellent customer support to ensure your projects and facilities run smoothly
Our technical staff is made up of industry experts who have a complete understanding of our product family.

Being a First Class manufacturer and business partner is a major part of our corporate values and our commitment to our customers and authorized distributors.
  • We think globally and act locally
  • Product manufacturing is ISO 9000 certified
  • Product architecture enables customized configuration options
  • Established local sales, business development, marketing, product support and operations departments means you’ll have your questions answered and the right products delivered on time. We work with our authorized distributors to offer support ranging from project planning and design, commissioning of the facility, maintenance and operator training and more. It is dedication and support that make Xtralis Pty Ltd a leader in the industry. We ensure the support you need is available to you in many different methods - from telephone, email, and world wide web to standing next to you at a job site—we know how important the simplest principle of business can be.

Back to Top



Systems are cost effective to install and have low maintenance costs
The Laser product range includes detectors for small environments to large open spaces. A single detector can cover an area of up to 2000 m2 (20,000 sq. ft). The pipe network can consist of simple, inexpensive pipe.

Retrofit is also cost effective as the pipe network can be installed in existing ductwork or hidden in the ceiling ... and interface to existing fire alarm panels is seamless.

In areas where maintenance access is difficult, detectors can be wall mounted in one central area either inside or outside of the protected location. All maintenance and testing can be performed at the detector... saving time and money.

Extending a system to protect new areas may be as simple as running some extra pipe.

In areas where tampering or vandalism could cause nuisance alarms and maintenance problems, provides a very cost effective solution.

Back to Top



Detectors have been approved by many regulatory bodies worldwide so you can be sure you are using compliant products

Logo  Logo  Logo  Logo  Logo  Logo  Logo



Back to Top



Home Products Brochure Hypoxic Air Video Executive Team FAQ's Contact Us Site Map